
Overvis MC251
The AI gateway for industry
A gateway that puts industrial equipment in front of the AI. Mount it, wire the bus and enter its PIN in Overvis HMI, and every device is found and set up from its manual.
Then €1.00 a month while it is enabled.

Set up by the AI
Devices found and set up from their manuals
RS-485 serial
Modbus RTU and ASCII
Modbus TCP
Devices on the site network
WireGuard VPN
Built in and always on
4G/LTE
With GSM fallback
Ethernet
10/100 RJ45 port
microSD card
Readings kept while offline
DIN rail
IP20, 9 to 30 V DC
Setup by the AI
Finds the devices
The MC251 in the plant room is powered and online. What's on its bus?
- Scan bus · RS-485, 9600 bps, addresses 1 to 247
- Identify · 4 devices
- Read manuals · 3 found
Four devices, three of them ready.
I named them and set up their values from the manuals. The Carel pCO5 at address 12 has no manual yet; I'm reading its register map from the controller.
Devices found on the bus
- Set up
Danfoss AK-CC 550
Address 7 · 38 registers
- Set up
Schneider PM2100
Address 3 · 24 registers
- Set up
ABB ACS580
Address 5 · 41 registers
- Identifying
Carel pCO5
Address 12 · reading the manual
Ask what is behind the gateway. The assistant scans the bus, identifies each device by its registers and gives it a name you recognise.
Sets them up from the manual
AK-CC 550 manual.pdf
This is the controller in cold room 3.- Read manual · 212 pages
- Read device · address 7, 38 registers
- Compare · 14 values with the manual's ranges
Danfoss AK-CC 550 at address 7, added with 14 values.
Each reading against the range the manual gives for a chilled room. One is outside it:
| Value | Reading | Manual |
|---|---|---|
| Room temperature | 2.8 °C | 2 to 4 °C |
| Evaporator temperature | -1.4 °C | -5 to 0 °C |
| Defrost interval | 6 h | 4 to 8 h |
| Superheat | 12.6 K | 4 to 8 K |
Superheat is above the manual's range: the expansion valve is underfeeding. Section 7.3 covers the fix.
Message...
It reads the manual or register map of each device, sets up its values, units and ranges, and checks every reading against the manual.
Runs on site, even offline
If the internet drops, keep the cold rooms below −18 °C and log every room each minute.
- Wrote program · Cold room fallback, 46 lines
- Checked · against the four devices on the bus
Done. It runs on the MC251 itself, so it works with no connection at all.
Assistant action
Do you allow the assistant to install the program “Cold room fallback” on the MC251?
- Gateway
- MC251 · Cold store
- Runs
- While the cloud is unreachable
- Logs to
- microSD, every minute
Ask for logic that must not depend on the internet, and you get a program that runs on the gateway itself, installed once you allow it.
Setup by PIN
Add a gateway
Enter the PIN printed on the gateway's label.
Power it and enter the PIN from its label in Overvis HMI, and the gateway is in your workspace, ready for the AI.
VPN by default

All traffic runs through the device's own WireGuard tunnel. The tunnel opens outward on start-up and stays up, behind NAT and ordinary firewalls.
4G/LTE and Ethernet

Wired where the site has a network, 4G/LTE where it does not, both through the same tunnel. Readings are kept on the device while a link is down.
Common applications
Questions about your equipment
Ask why a pump stopped or which room is drifting, in your own language. The answer comes from live values, history and the manuals.
Predictive maintenance
A current that creeps up or a defrost that takes longer each week shows in the history. Ask, and the AI reads the trend and sets up an alarm for it.
Many sites, one workspace
Put a gateway in every branch, store or pump station and see all of them in one place, with the same AI across the fleet.
Remote sites over 4G/LTE
Containers, pump stations and outdoor cabinets with no network of their own get online through the mobile link.
Energy and reports
Ask for energy reports, audits and savings proposals from the meters on the bus.
Alarms by SMS
State a limit in one sentence, and the AI sets up the alarm. When the limit is crossed, an SMS or email goes out.
Technical specifications
Serial
- Interface
- RS-485, half-duplex, 2-wire
- Speed
- 75 to 230,400 bps
- Driver output
- 3.3 V, short circuit protected to 250 mA
- Built-in terminator
- 1000 Ω
Modbus
- Protocols
- Modbus RTU and ASCII
- Devices on the bus
- Up to 32 with 1 mA inputs, up to 256 with 0.125 mA inputs
Ethernet
- Port
- 1 × RJ45, 10/100 Mbit/s, auto MDI/MDIX
Mobile
- Module
- LTE Cat. 1 with GSM fallback
- Bands
- GSM 900/1800, LTE B1, B3, B5, B7, B8, B20
- SIM
- Mini-SIM (2FF), not included
Network
- Uplink
- Ethernet or 4G/LTE, chosen automatically
- VPN
- WireGuard
- Protocols
- TCP, UDP, IPv4, DHCP, DNS, NTP, HTTP, Modbus TCP
System
- Storage
- microSD, 2 GB card included
- On the device
- Display, status LEDs, real-time clock, astronomical timer
- Firmware updates
- Over the network or from microSD
- Ready after power-up
- Within 15 s
Power
- Supply
- 9 to 30 V DC, 12 V rated
- Consumption
- Up to 6 W
Physical
- Mounting
- 35 mm DIN rail, any position
- Dimensions, H × W × D
- 64.5 × 90.2 × 36 mm
- Weight
- Up to 400 g
- Housing
- Self-extinguishing plastic
Environment
- Operating temperature
- −35 to +55 °C
- Humidity
- 30 to 80 %, non-condensing
- Protection
- IP20, class III, overvoltage category II
- Service life
- 10 years
In the box
- Overvis MC251
- Ethernet cable
- GSM antenna, SMA
- 2 GB microSD card
- Operation manual
SIM card and power supply are not included.
MC251 or MC252
| MC251This page | MC252See MC252 | |
|---|---|---|
| Price, excl. VAT | €68 | €128 |
| Voucher for usage | €30 | €30 |
| The AI sets it up in Overvis HMI | ||
| SCADA, HMI panels and other Modbus TCP software | – | |
| Web interface and HTTP API on the device | – | |
| Warranty | Five years | Five years |
Frequent questions
Does the MC251 work without Overvis HMI?
No. It connects only to Overvis HMI. For SCADA, HMI panels or your own software, choose the MC252.
What happens when the connection drops?
The gateway keeps reading the devices and stores the readings. When the link returns, they are sent and the history has no gap. Programs on the gateway keep running throughout.
Do I need a static IP address or port forwarding?
No. The MC251 connects out through its WireGuard tunnel and works behind NAT and ordinary firewalls.
Which ports does a firewall have to allow?
Outbound TCP 80 for the first handshake and outbound UDP for the WireGuard tunnel, plus DNS and NTP if your network restricts them.
How many devices can one MC251 serve?
Up to 32 on a typical RS-485 bus with 1 mA inputs, and up to 256 with 0.125 mA inputs. Wiring and bus load set the real limit.
What SIM card does it take?
A standard Mini-SIM. The APN is detected automatically and can be changed on the device. The SIM card is not included.
How much mobile data does it use?
About 50 bytes per value read, plus VPN overhead. Ten devices with 20 values read every minute use around 430 MB a month; read every five minutes, about a fifth of that.
What does it cost to run?
€1.00 a month while it is enabled, charged by the hour from your prepaid balance, plus the values it reads and the history you keep. The pricing page has a calculator.
Is a power supply included?
No. It needs 9 to 30 V DC, 12 V rated, and draws up to 6 W through a two-pin terminal.
What does the warranty cover?
Five years from the date of sale. A faulty device is repaired free of charge.